Order online / Pick up in store

Order online! Pick up in store! Reservation service

Reservation service

Learn more
My storeMy storeEdit

Customer rating:

  • Same-day delivery
  • Advertisement
  • Available for reservation
  • Store pickup

GreenGuard XP14 Fanfold Underlayment|其他商品

其他商品 综合商品 其他商品
GreenGuard XP14 Fanfold Underlayment|其他商品

Online price
Price including tax

1,746.00USD

  • eckerundpartner.at
    Please check the product information

About Komeri points

Decrease quantity
Increase quantity

    Pick up in store Pick up in store
    (Free shipping)

    Pickup store:

    Choose a store

    Check nearby stores

    Estimated availability:

    1 PMOrder by this time →5 PMReady by this time

    5 PMOrder by this time →The next morningReady by this time

    Pickup options and shipping fees

    Add to cart

    Delivery Delivery

    Estimated availability:

    Estimated delivery around October 29.

    Available for credit card and cash on delivery payments only. For other payment methods, seeherefor details.

    Orders on weekends or public holidays and stock availability may affect delivery times.

    Same-day shipping conditions

    Pickup options and shipping fees

    Add to cart

    Add to wishlist

    Added to wishlist

    Details of GreenGuard XP14 Fanfold Underlayment|其他商品

    Top-of-the-line Facers
    Kingspan's premium choice ¼” (0.25") thick closed-cell extruded polystyrene (XPS) fanfold underlayment with our best perforated facers on both sides for use in replacement siding operations; designed to be used as a “leveling board”, adding insulation and moisture protection in installation of new vinyl siding over old siding. It is configured in fanfolded bundles 4’ x 50’ with cut-n-fold hinges which improves its ability to lay flat. It is lightweight, easy to cut, and install.


    Product Highlights



    Kingspan's top-of-the-line facers
    Lay flat cut-and-fold hinges
    Perforated to allow moisture vapor to escape

    Does fanfold provide good insulation value?
    The primary purpose of fanfold is to level out the walls, so the new siding goes on straight. Fanfold does provide some additional R-Value to the wall depending on the thickness. 
    Should the reflective surface be placed to the outside or the inside?



    Since reflective surfaces are designed to reflect radiant heat, it is common practice to install the radiant surface to the predominantly warm side of the wall. In an extremely cold climate, that would mean installing with the reflective surface inward. In a hot climate, it would be installed with the radiant surface outward. In climates that are more balanced, it may be installed either way, depending on whether the objective is to reduce heat loss in winter or reduce heat gain in summer.
    Some GreenGuard siding underlayments have a reflective surface and claim a higher R-Value. How does this work?
    Reflective surfaces reflect (do not emit) radiant heat. For example, our 3/8” thick siding underlayment has an R-Value of 1.5. With a reflective surface, the effective R-Value of that product can be as high as 3.5, when installed using a ½” uniform, parallel dead air space on the reflective side. This follows the “ASHRAE Handbook of Fundamentals” basic principles of reflective insulation properties. With the air space partially achieved, the effective R-Value is something between the 1.5 of the foam and the maximum 3.5. Be aware that some manufacturers may make misleading claims of very high R-Values achieved with reflective surfaces. 
    Should I install the fanfold or building wrap first?
    Depends. If you are doing a full siding tear off and replacing the whole window units it is recommended to install the fanfold first and then the building wrap on top. You will then install the windows on top of these layers and flash accordingly. If you are keeping the existing windows, it is often easier to install the building wrap first to flash it to the existing window and then install the layer of fanfold on top.
    Can fanfold siding underlayment be used in place of building wrap?
    GreenGuard siding underlayments are in compliance with the ICC-ES “Acceptance Criteria for Foam Plastic Sheathing Panels Used as Weather–resistive Barriers” (AC71). This means that GreenGuard fanfold siding underlayments may be used in either new or retrofit construction applications without an additional water-resistive barrier (felt building paper or building wrap), when they are installed in strict accordance with the installation instructions. 
    Documents

    Insulation Board Line Sheets
    Product Data Sheet
    Safety Data Sheet (SDS)
    Installation Guides

    Technical Info

    GreenGuard XP14 can be used in the residential, commercial, etc. applications.
    GreenGuard is Extruded Polystyrene (XPS)
    GreenGuard XP14 is 4' wide and 50' long

    Code Compliance

    Code Compliance Research Reports: CCRR-1022






    .pdp-description-table{width:100%;}.pdp-table-tr{display:flex;justify-content:space-between;}.pdp-table-td{padding:12px 16px;text-align:left;border:none;}.pdp-table-td:first-child{font-weight:bold;width:30%;}.pdp-table-td:nth-child(2){width:70%;}
    Brand:KingspanSKU:XP14Tags:Building Materials, Call for Pricing, Insulation Board, Recommendations disabledSize/Quantity:1/4" x 4' x 50' - 128 Squares
    • GreenGuard XP14 Fanfold Underlayment|其他商品
    • GreenGuard XP14 Fanfold Underlayment|其他商品
    • GreenGuard XP14 Fanfold Underlayment|其他商品

    Find products in the same category

    Recommended 其他商品 products

    See more in this category

    Customers who viewed this item also viewed

    Products at nearby stores

    See more in this category

    Customer reviews

    Customer rating: