Order online / Pick up in store

Order online! Pick up in store! Reservation service

Reservation service

Learn more
My storeMy storeEdit

Customer rating:

  • Same-day delivery
  • Advertisement
  • Available for reservation
  • Store pickup

GreenGuard PB6W Roofing Cover Board - 3/8" x 4' x 50' - 1056 Squares| Other Products

Other Products General Merchandise Other Products
GreenGuard PB6W Roofing Cover Board - 3/8" x 4' x 50' - 1056 Squares| Other Products

Online price
Price including tax

7,408.24USD

  • eckerundpartner.at
    Please check the product information

About Komeri points

Decrease quantity
Increase quantity

    Pick up in store Pick up in store
    (Free shipping)

    Pickup store:

    Choose a store

    Check nearby stores

    Estimated availability:

    1 PMOrder by this time →5 PMReady by this time

    5 PMOrder by this time →The next morningReady by this time

    Pickup options and shipping fees

    Add to cart

    Delivery Delivery

    Estimated availability:

    Estimated delivery around October 29.

    Available for credit card and cash on delivery payments only. For other payment methods, seeherefor details.

    Orders on weekends or public holidays and stock availability may affect delivery times.

    Same-day shipping conditions

    Pickup options and shipping fees

    Add to cart

    Add to wishlist

    Added to wishlist

    Details of GreenGuard PB6W Roofing Cover Board - 3/8" x 4' x 50' - 1056 Squares| Other Products

    PB6W Roofing Cover Board is a 3/8” thick closed-cell extruded polystyrene (XPS) fanfold with high-impact white facers on both sides.
    With the ease of insulation and low water absorption, it is ideal for use with mechanically-fastened and ballasted EPDM, TPO & PVC single-ply roof membranes. Compare to alternates based on weight, durability, product cost, handling, and installation labor to see why the PB6W is your best choice. PVC manufacturer should be contacted to confirm approval.
    Kingspan GreenGuard PB6W Product Data Table

    Product Highlights

    High-impact white facers
    Highly moisture resistant
    UL Classified
    Maintains integrity

    Does fanfold provide good insulation value?
    The primary purpose of fanfold is to level out the walls, so the new siding goes on straight. Fanfold does provide some additional R-Value to the wall depending on the thickness.
    Should the reflective surface be placed to the outside or the inside?
    Since reflective surfaces are designed to reflect radiant heat, it is common practice to install the radiant surface to the predominantly warm side of the wall. In an extremely cold climate, that would mean installing with the reflective surface inward. In a hot climate, it would be installed with the radiant surface outward. In climates that are more balanced, it may be installed either way, depending on whether the objective is to reduce heat loss in winter or reduce heat gain in summer.
    How can I use foam sheathing in place of wood sheathing and maintain structural stability?
    XPS foam sheathing not only offers better insulation than wood sheathing, but it also provides water resistance. You can use GreenGuard XPS foam sheathing in place of wood sheathing by employing alternate bracing methods such as “let-in bracing” or steel strapping to achieve structural properties. Another alternative is to use wood sheathing in the corners to achieve structural properties and foam sheathing in the non-structural portions of the wall. This approach is done following the “prescriptive method” outlined in the codes. Another simple option is to sheath the house completely in wood and install a layer of XPS insulation on the exterior as added insulation. Please reference our Technical Evaluation Report - TER 1410-09 / Attachment of Exterior Wall Coverings through Kingspan GreenGuard XPS Sheathing to Wood or Steel Wall Framing.
    Some GreenGuard siding underlayment have a reflective surface and claim a higher R-Value. How does this work?

    Reflective surfaces reflect (do not emit) radiant heat. For example, our 3/8” thick siding underlayment has an R-Value of 1.5. With a reflective surface, the effective R-Value of that product can be as high as 3.5, when installed using a ½” uniform, parallel dead air space on the reflective side. This follows the “ASHRAE Handbook of Fundamentals” basic principles of reflective insulation properties. With the air space partially achieved, the effective R-Value is something between the 1.5 of the foam and the maximum 3.5. Be aware that some manufacturers may make misleading claims of very high R-Values achieved with reflective surfaces. 
    Should I install the fanfold or building wrap first?
    Depends. If you are doing a full siding tear off and replacing the whole window units it is recommended to install the fanfold first and then the building wrap on top. You will then install the windows on top of these layers and flash accordingly. If you are keeping the existing windows, it is often easier to install the building wrap first to flash it to the existing window and then install the layer of fanfold on top.
    Documents

    Insulation Board Line Sheets
    Product Data Sheet
    Safety Data Sheet (SDS)
    Installation Guides

    20 Year Warranty

    Technical Info

    GreenGuard PB6W can be used in the residential, commercial, etc. applications.
    GreenGuard is Extruded Polystyrene (XPS)
    GreenGuard PB6W Roofing Cover Board is 4' wide and 50' long.

    Code Compliance

    Code Compliance Research Reports: CCRR-1022
    Brand:KingspanSKU:PB6W*Tags:Building Materials, Call for Pricing, Recommendations disabled, Roof Cover Board
    • GreenGuard PB6W Roofing Cover Board - 3/8" x 4' x 50' - 1056 Squares| Other Products

    Find products in the same category

    Recommended Other Products products

    See more in this category

    Customers who viewed this item also viewed

    Products at nearby stores

    See more in this category

    Customer reviews

    Customer rating: